YS-475 PCR
----
Technical Specification
- Gradient PCR machine with touch screen interfaced Silver/Aluminum block system for 96 x0.1/0.2 mL PCR Tube or One 96-well PCR plate
-
2-Dimensional Gradient for advanced PCR optimization
- capable of testing different temperatures in 12 columns and 8-rows simultaneously across a gradient range of 1 - 30°C
-
Gradient technology is preferably operated on Steady Slope to ensure ramp rates are identical inboth gradient and normal operation
-
Adjustable user management capabilities: from flexible to strict user level controls
-
Heating of the block should be through six or more peltier block elements
-
Temperature control range: from 4°C to 99°C with Fast Intermediate Standard and Safeoperational mode
-
Lid Temperature range: 38° - 110°C
-
Block Temperature Accuracy: ± 0.15°C
-
9. Block Homogeneity: 20° C to 72° C: ≤ ±0.2° C
- 95° C: ≤ ± 0.3° C
-
10. Heating ramp rate: 5°C/s or more
-
11. Cooling ramp rate: 2°C/s or more
-
12. Adjustable ramp rate individually for heating & cooling
-
13. Lid descent and closing pressure should be optimum for tube/plate of different capacities
-
14. Intuitive Graphic programming with larger display
-
15. Administrator and user login with PIN or password for enhanced security
-
16. Preprogrammed template for easy selection of PCR protocols
-
17. Time or Temperature increment with cycles in PCR program
-
18. Customized programming should allow at least 37 steps and 99 cycles
-
19. Auto Restart facility with user defined time interval when power fails and resumes
-
20. Log book function for error messages and new calibration
-
21. Flexibility to transfer programs with constant parameters from other cycler models
-
22. Cooling vents at bottom and rear allow placing other instruments in limited bench space
-
23. Option to connect five or more similar system for high-throughput use
-
24. Instrument should RoHS compliance system along with CE & ISO
-
25. Interface: Ethernet USB
-
26. Power supply: 110-230 V
- 50-60 Hz
-
27. Heat Sealer should be reliable and effective sealing of a variety of plates like large deep well plates to low profile PCR plates
- 96- and 384-well plates
-
28. In Heat sealer Integrated thermostat should prevents overheating and temperature should be around 150o-180 °C
-
29. In Heat sealer Operating Temperature should be 18°C to 30°C and operating Humidity 20 % to80 % non-condensing
-
30. Should provide at least one year warranty certificate for PCR and heat sealer.
-
31. Should provide with a 2 KVA on-line UPS with a minimum 30 min power backup.
-
32. Should provide authorization certificate
33. Installation
- Demonstration and time to time service as and when necessary.